3
©2012 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com for current information.
TVS Diode Arrays (SPA
®
Diodes)
Revision: November 29, 2012
SP6003 Series
SP6003
ESD and EMI Filter Devices - SP6003 Series
Line Capacitance vs. DC Bias
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
0.00.5 1.01.5 2.02.5 3.03.5 4.04.5 5.0
DC Bias (V)
Capacitance (pF)
Time
Temperature
T
P
T
L
T
S(max)
T
S(min)
25
t
P
t
L
t
S
time to peak temperature
Preheat
rehea
Ramp-up
amp-up
Ramp-down
amp-d
Critical Zone
T
L to TP
ritical Zon
to
Reflow Condition Pb – Free assembly
Pre Heat
- Temperature Min (T
s(min)
) 150°C
- Temperature Max (T
s(max)
) 200°C
- Time (min to max) (t
s
) 60 – 180 secs
Average ramp up rate (Liquidus) Temp
(T
L
) to peak
3°C/second max
T
S(max)
to T
L
- Ramp-up Rate 3°C/second max
Reflow
- Temperature (T
L
) (Liquidus) 217°C
- Temperature (t
L
) 60 – 150 seconds
Peak Temperature (T
P
) 260
+0/-5
°C
Time within 5°C of actual peak
Temperature (t
p
)
20 – 40 seconds
Ramp-down Rate 6°C/second max
Time 25°C to peak Temperature (T
P
) 8 minutes Max.
Do not exceed 260°C
Soldering Parameters
Product Characteristics
Lead Plating Pre-Plated Frame
Lead Material Copper Alloy
Lead Coplanarity 0.0004 inches (0.102mm)
Substitute Material Silicon
Body Material Molded Epoxy
Flammability UL 94 V-0
Notes :
1. All dimensions are in millimeters
2. Dimensions include solder plating.
3. Dimensions are exclusive of mold flash & metal burr.
4. Blo is facing up for mold and facing down for trim/form, i.e. reverse trim/form.
5. Package surface matte finish VDI 11-13.
Part Numbering System
SP
6003
** U T
G -1
Series
Package
µ
DFN-08 (1.7x1.35mm)
µ
DFN-12 (2.5x1.35mm)
T= Tape & Reel
G= Green
Number of Channels
04 = 4 Channel
µ
DFN-08
06 = 6 Channel
µ
DFN-12
–
Ordering Information
Part
Number
Package Size Marking Min.
Order
Qty.
SP6003-04UTG-1 µDFN-08 1.7x1.35mm
C114
3000
SP6003-06UTG-1 µDFN-12 2.5x1.35mm
C116YYWW
3000