Radial Lead Fuses
TE5
®
> Time-Lag > 400 Series
400 Series, TE5
®
, Time-Lag Fuse
Agency Approvals
Agency Agency File Number Ampere Range
E67006 800mA – 6.3A
JET1896-31007-2001
JET1896-31007-1003
1A – 5A
6.3A
DE1-40597 500mA – 6.3A
CQC09012031624 500mA – 6.3A
SUS05024-9004 500mA – 800mA
SUS05024-9003 1A – 2.5A
SUS05024-9001 3.15A
SUS05024-10003 4A – 5A
SUS05024-9002 6.3A
Features
Electrical Characteristics
• Lead-freeandRoHS
Compliant
• ReducedPCBspace
requirements
• Directsolderableorplug-
in versions
• Lowinternalresistance
• Shocksafecasing
• Vibrationresistant
• Halogen-free
% of Ampere
Rating
Opening Time
150% 1 Hour, Minimum
210% 120 Secs., Maximum
275% 400 ms, Minimum; 10 Secs., Maximum
400% 150 ms, Minimum; 3 Secs., Maximum
1000% 20 ms, Minimum; 150 ms, Maximum
Electrical Characteristics
Amp
Code
Rated
Current
Rated
Voltage
Breaking Capacity
Voltage
Drop
1.0×I
N
max. (mV)
Power
Dissipation
1.0×I
N
max. (mW)
Melting
Integral
10×I
N
max. (A
2
s)
Agency Approvals
0500 500mA 250V
130A/250VAC*
50-60 Hz cos
ϕ
= 1.0
165 297 2.17
x x x x
0800 800mA 250V 116 387 6.72 x x x x
1100 1.00A 250V 89 432 9.63 x x x x x
1125 1.25A 250V 76 411 14.44 x x x x x
1160 1.60A 250V 76 601 21.75 x x x x x
1200 2.00A 250V 75 758 32.16 x x x x x
1250 2.50A 250V 61 683 61.94 x x x x x
1315 3.15A 250V 55 921 101.61 x x x x x
1400 4.00A 250V 65 936 133.40 x x x x x
1500 5.00A 250V 56 948 216.50 x x x x x
1630 6.30A 250V 48 926 318.71 x x x x x
* Per VDE, approved breaking capacity is at 100A, 250VAC
The 400 Series is a TE5
®
, Time-Lag type subminiature fuse
designed for overcurrent protection. It is 250V rated and
designed in accordance to IEC 60127-3.
Description
Applications
• Batterychargers
• Consumerelectronics
• Powersupplies
• Industrialcontrollers
Additional Information